Browse all practice questions for the Fire Pump Run Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Fire Pump Run Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • When operating a deck gun, what is the proper procedure for adjusting the stream without losing prime?
  • What safety steps should be followed when starting or stopping a fire pump?
  • Why is it important to match nozzle pressure to the attack line length and diameter?
  • Which action is part of post-run checks after shutting down the pump?
  • Which statement about inspecting the pump assembly is correct?
  • What is the purpose of a backflow prevention device in hydrant connections?
  • What steps should the operator take if the pump gauge indicates air in the discharge lines?
  • Which statement best describes static water head and friction head in relation to PDP?
  • When calculating friction loss for a practice scenario, which factors must be included?
  • What shall be posted at each fire department connection and system control valve indicating which system, or part thereof, has been removed from service?
  • Which statement correctly defines back pressure in pump operations and its effect on nozzle performance?
  • What is a Siamese discharge and why is it used?
  • The pump driver shall overload beyond its rating (including any service factor allowance) when delivering the necessary brake horsepower.
  • A maintenance program shall be established based on whose recommendations?
  • How can you minimize risk of backflow when connecting to a live hydrant?
  • The energy source for the pump driver shall supply which measure to meet system demand?
  • How does elevation affect required discharge pressure when pumping to a higher level?
  • A valve installed as a safety valve shall:
  • Which action should be taken if air leaks are detected in the suction line during priming?
  • What is a consequence of abrupt throttling during pump start or stop?
  • How can you identify and prevent cavitation on the suction side of a pump?
  • What are key safety practices when working around a running pump in a tight space?
  • What is the primary purpose of NFPA 20 in fire pump installations?
  • What adjustments would you make if the discharge pressure is too low to meet the requested nozzle pressure?
  • Which of the following lists the common signs of a leaking suction line?
  • Why is consistent training important for fire pump operators?
  • When using a deck gun, what must be accounted for in determining discharge pressure?
  • In priming sequence, which valve should be opened first?
  • Approximately how many drops per second are necessary to keep packing lubricated?
  • The electrolyte level in the batteries should read:
  • During a run, how should a pump operator interact with the engine governor?
  • When multiple hoses are needed, what is the typical approach to opening discharge valves?
  • What is friction loss and how does it affect pump operation?
  • NFPA 2006 California Edition is based on:
  • What are the signs that a pump has successfully primed?
  • Which statement best describes the effect of nozzle design on pressure for a given flow?
  • What is the purpose of priming during pre-run checks?
  • In master stream operations, what primarily drives the need for greater pump output?
  • What is the primary purpose of a discharge relief valve in a fire pump system?
  • What should be included when documenting pump runs for training or compliance?
  • In a multi-line system, what is the consequence of not balancing flows?
  • Why is it important to verify valve positions during pre-run checks?
  • How does friction loss depend on flow rate?
  • The purpose of testing the pump assembly includes ensuring automatic manual operation upon demand and continuous delivery of the required system output. An additional purpose is to:
  • Flow condition and fire pump alarm signals tests should occur how often?
  • An automatic timer shall NOT be permitted to be substituted for the starting procedure.
  • What is the difference between handlines and master streams in terms of required pressure?
  • Which of the following is NOT a common power source for fire pumps?
  • Explain the role of a deck gun (master stream) and its nozzle pressure considerations.
  • What is the primary purpose of the fire pump governor on a diesel-powered apparatus?
  • What is a recommended method to verify nozzle flow at the discharge during testing?
  • Why is pump discharge pressure typically not equal to nozzle pressure?
  • What is the purpose of performing a pre-incident pump test?
  • If pump head is 60 ft and system losses are 25 ft, what is net pump head?
  • In pump calculations, what does PDP stand for?
  • What is the recommended action after priming is complete?
  • To check the automatic stop controller, what is recorded?
  • No-flow condition pump operation for electric motor driven fire pumps shall be conducted how often?
  • Which of the following actions is NOT part of the initial steps you take before starting a fire pump in the engine mode?
  • Pump packing boxes, bearings and casing shall be checked for __________.
  • What is the purpose of a master stream device such as a deck gun or portable monitor on a pumper?
  • The California edition of NFPA 2006 is based on which NFPA 25 edition?
  • Tanks not equipped with supervised water level alarms connected to a constantly attended location shall be inspected:
  • PDP stands for pump discharge pressure. Which description best matches its role during a run?
  • Under normal conditions, what should the state of the normal phase rotation pilot be?
  • What is the importance of maintaining proper alignment between the pump and drive system?
  • Which of the following is NOT a component of TDH?
  • What does friction loss represent in pump operations?
  • For both Electric & Diesel pumps, the wet pit suction screens should be:
  • What is the best practice for testing a discharge line when diagnosing low flow conditions?
  • What is the purpose of establishing prime in a pump operation?
  • What is a comprehensive method to verify that the correct discharge valve is open when multiple lines are in use?
  • Diesel engine system conditions are part of which inspection scope?
  • Why is nozzle selection important for a given fire scenario?
  • How do pre-connect lines differ from master stream lines in terms of typical flow and nozzle size?
  • Which action best ensures personnel safety before advancing a deck gun into a potential structure fire?
  • During weekly inspection, the water level in the suction reservoir should be:
  • What start method is required for weekly fire pump test?
  • For centrifugal fire pumps, which pairing describes the two stage configurations and shaft orientations?
  • What common mechanical issues can cause an abnormal pump noise and should be checked first?
  • For a 150 ft run with friction loss of 9 psi per 100 ft, what is the friction loss and the required nozzle pressure to maintain PDP of 120 psi?
  • Which of the following is a common sign of a suction-side air leak?
  • If a discharge valve fails to open, which sequence best describes the recommended action?
  • When relay water between pumpers becomes necessary, what is the key consideration to ensure safe operation?
  • True or False: A license is required for inspection.
  • In the recommended sequence to place a pump in service at an incident, what is the step that follows completing pre-checks?
  • In drafting, what is the purpose of priming the pump?
  • What is the purpose of establishing a safe operating range for the deck gun?
  • Which position should the controller selector switch be in?
  • What is the purpose of a flow meter or gauge on the discharge side?
  • The battery electrolyte level reading should be in which range?
  • What is the purpose of the intake relief valve on some fire pump setups?
  • Why is it important to practice pump operations with both hydrant and drafting scenarios?
  • What is friction loss and why is it important in pump calculations?
  • The weekly test pertinent adjustments shall be made while the pump is:
  • What is the purpose of inspecting the pump assembly?
  • The fire pump shall be started manually for the test run. True or False?
  • Which action is recommended to avoid pressure surges when starting the pump?
  • If a gauge shows zero pressure at the discharge while the engine is at full RPM, what should you verify?
  • Which sequence correctly describes a safe shutdown procedure for a fire pump after operations?
  • Which statement about the isolating switch for electric pumps is correct?
  • The weekly test duration for diesel pumps should be how many minutes?
  • On a diesel engine system, how often should solenoid valve operation be visually inspected and then tested?
  • What action should be taken if suction air leaks are suspected during pump priming?
  • Which statement is true about inspection licensing?
  • Which of the following is included in the weekly inspection categories for pump operations?
  • Why is it important to keep the suction line free of air during pump operations?
  • Preventative maintenance program shall be established on:
  • How can you prevent water hammer when opening discharge valves?
  • When the suction gauge shows zero or a vacuum, how should priming be checked?
  • During the test, which pressure gauge readings are required to be recorded?
  • When using a pump panel, what should you verify after switching to governor mode?
  • The oil level in the vertical motor sight glass should be within what range?
  • If a safety valve is installed, what is its primary function?
  • How do you determine the friction loss for a given hose size and flow in a practice scenario?
  • What is the purpose of a relief valve in the pump output circuit?
  • Maintenance program shall be based on whose recommendations?
  • Which of the following is NOT typically associated with an emergency impairment?
  • Which device maintains discharge pressure by adjusting engine speed in response to system demand?
  • On diesel engines, if cooling water discharge is not adequate, which two components should be checked for obstructions and adjusted for correct flow?
  • How often should all pressure relief valves be inspected?
  • For horizontal pumps, the nameplate specifies a target pressure difference. What is this pressure called?
  • Which steps comprise a simple flow test to verify pump performance with a known nozzle?
  • The number of engine operating hours is measured by the:
  • Which step is not part of addressing air in discharge lines?
  • Which of the following items is checked during weekly visual inspections of the diesel-powered pump system?
  • On horizontal pumps, the difference between suction and discharge pressures should match which pressure as shown on the fire pump nameplate?
  • What is the role of a governor on a fire pump engine?
  • All alarm pilot lights should be in what state?
  • Which term describes the speed referenced as full speed for electric systems and running speed for diesel and steam systems?
  • True or False: On an electrical system, motor bearings should be greased annually.
  • True or False: NFPA 25 does not apply to sprinkler systems but NFPA 13D does.
  • Which device indicates the total hours the engine has been running?
  • What is a master stream appliance, and how is it used during fires?
  • Total dynamic head (TDH) in feet is defined as the sum of static head, friction losses, and minor losses, with appropriate conversions between psi and feet when needed.
  • True or False? The transfer switch normal pilot light should be illuminated.
  • Which statement about friction loss and elevation head is true?
  • In the weekly checks, the transfer switch normal pilot light should be in what state?
  • How is nozzle pressure used in calculating PDP for a given attack line?
  • Which item indicates which portion of the system has been removed from service?
  • No-flow condition pump operation for diesel engine driven fire pumps shall be conducted at what frequency?
  • Where should a suction hose be positioned for drafting?
  • Explain how to use a pump panel to switch between manual and governor-controlled operation if available.
  • Which option describes the prescribed horsepower for the pump driver?
  • The pertinent visual observation categories required to be inspected weekly checklists are:
  • What is the proper sequence to recover a prime after a long layoff if the pump becomes air-bound?
  • After repairing a stuck priming valve, what is the recommended verification step before using the pump again?
  • Which items are included in a routine pre-run test?
  • Which action is best as an initial check when a pump cannot prime due to a stuck or unlocked priming valve?
  • Which sequence correctly describes priming a diesel fire pump that is not yet primed?
  • Under normal operation, what should the state of the reverse phase alarm pilot light be?
  • Controllers include air-, __________ or electric- operated units.
  • Which component's oil level should be checked to ensure proper lubrication of the gear train?
  • What level of water discharge should the packing glands have?
  • What type of information should maintenance records include to support NFPA 20 compliance?
  • Why is it important to inspect suction strainers?
  • How often should diesel engine fuel tank level, float switch, and solenoid valve operation be checked?
  • Elevation head is the additional pressure needed to lift water to the target height.
  • Heat exchangers shall be checked for __________ water flow.
  • What is the purpose of a discharge relief valve?
  • What is involved in a cascade pumping arrangement?
  • What is the required start method for weekly fire pump testing?
  • An automatic weekly test timer shall be substituted for the normal starting procedure of the weekly test.
  • Testing and maintenance is per which NFPA code?
  • Explain the relationship between nozzle pressure and GPM.
  • Which gauge condition on the suction side indicates a risk of cavitation and should prompt corrective action?
  • What is the purpose of a pump intake screen (strainer) when drafting?
  • If static head is 25 ft and friction losses are 10 ft with no minor losses, what is the TDH in feet?
  • If the measured discharge flow does not match the expected value, what is a likely cause to check first?
  • The oil level in the right angle gear drive should be within what range?
  • Before starting the pump, you should close the intake valve.
  • What is the primary reason to balance flows when using multiple discharge lines simultaneously?
  • Which set of information should be included when documenting a pump run for compliance?
  • In the recommended pump-in-service sequence, what action follows priming?
  • What is a typical nozzle pressure range for a fog nozzle used on a 1.75- or 2.5-inch attack line?
  • Is nozzle pressure the target pressure at the nozzle?
  • True or False? Fire Marshalls do NOT assign impairment coordinators.
  • Which action describes proper post-run pump maintenance?
  • Emergency impairments include system leakage, interruption of water supply, frozen or ruptured pipes and which of the following?
  • When would you use an unloader (relief) valve on the pump, and what does it do?
  • What could cause a pump to show a low suction pressure reading?
  • What is the function of a Siamese manifold on a pumper?
  • What is a relay pump operation?
  • What is cavitation, and how does it affect pump performance?
  • What steps would you take to clear a clogged nozzle in the field?
  • What kind of pump do you record the time crank?
  • How should you respond to a significant drop in discharge pressure while maintaining throttle?
  • Which statement correctly completes the requirement about the pump energy source and brake horsepower?
  • If a discharge valve fails to open, what is the recommended action?
  • How do you convert psi to feet of head?
  • What is the purpose of an intake relief valve on some systems?
  • What is the function of a discharge valve in the pump panel, and why must it be opened in a controlled sequence?
  • No-flow condition pump operation for diesel engine driven fire pumps shall be conducted how often?
  • What unit of measurement is used for pump discharge pressure on most engine dashboards?
  • Which is the correct minimum maintenance frequency for greasing motor bearings on electrical systems?
  • Which of the following are common water sources used for pump operations?
  • If you detect a continuous audible alarm or abnormal sound, what should you do?
  • The reverse phase alarm pilot light for electric pumps should be:
  • What does the suction gauge monitor in a centrifugal fire pump system?
  • Diesel fire pumps are required to be test ran weekly for how many minutes?
  • If the nozzle pressure is 70 psi, friction loss is 15 psi, and elevation head is 5 psi, what should PDP be?
  • What is the purpose of maintaining maintenance records for fire pumps?
  • Which of the following is a key indicator that a pump is not delivering the expected discharge despite high RPM?
  • What is the difference between drafting and relay pumping?
  • The normal phase rotation pilot should be:
  • During a simple flow test, which two parameters are monitored and compared against expected performance?
  • Static head is defined as which of the following?
  • Which combination indicates suction prime has been achieved?
  • When using a flowing water source, what is a key operational advantage over drafting from a static source?
  • There are two requirements listed under pump house conditions. Which statement is correct?
  • What is the consequence of misalignment between the pump and its drive system?
  • What is water hammer and how can it be prevented?
  • Wet pit suction screens should be cleaned how often?
  • As flow increases, which statement best describes friction losses?
  • Which statement best defines total dynamic head (TDH) in fire pump hydraulics?
  • What is the purpose of a jockey pump in a fire protection system?
  • When verifying the electrical system conditions, the controller pilot should be:
  • How do you verify a pump is delivering water to the discharge side?
  • What does governor do in a fire pump system?
  • Electric fire pumps are test ran weekly for how many minutes?
  • During operation, why are gauges monitored when opening discharge lines?
  • During priming, which observation indicates that suction is priming?
  • How do you verify the pump is delivering the required flow to all lines?
  • Describe how to prevent cross-connection and backflow when connecting to an outside water source.
  • When starting, record the time it takes for the motor to accelerate to what speed?
  • How can you determine if there is a kink or obstruction in a discharge hose causing low flow?
  • At what level should the fuel tank be?
  • Which of the following is the correct statement about substituting an automatic timer for starting procedures?
  • The water level in pressure tanks shall be within how many inches in non-pressure tanks within how many inches of the designated fire service level?
  • Which statement best describes the overall objective of testing the pump assembly?
  • What is the minimum temperature required in diesel pump rooms?
  • ________ inspection requires verification that the pump suction discharge and bypass valves should be fully open.
  • If cooling water discharge is inadequate on a diesel engine, which two components should be checked or adjusted?
  • The engine running time measurement is commonly referred to as the
  • What is net pump head?
  • When testing and observed that nozzle flow matches expected, what criterion confirms alignment?